Review




Structured Review

Abbott Laboratories amplatzer vascular plug ii
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer Vascular Plug Ii, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc12961297-34-13-17?v=Abbott+Laboratories
Average 86 stars, based on 1 article reviews
amplatzer vascular plug ii - by Bioz Stars, 2026-08
86/100 stars

Images

1) Product Images from "Use of a physician-modified candy plug to rescue gutter leak arising from a collapsed candy plug"

Article Title: Use of a physician-modified candy plug to rescue gutter leak arising from a collapsed candy plug

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

doi: 10.1016/j.jvscit.2026.102175

(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm Amplatzer Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Figure Legend Snippet: (A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm Amplatzer Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.

Techniques Used: Modification



Similar Products

86
Abbott Laboratories amplatzer vascular plug ii
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer Vascular Plug Ii, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc12961297-34-13-17?v=Abbott+Laboratories
Average 86 stars, based on 1 article reviews
amplatzer vascular plug ii - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer vascular plug ii avp ii
(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm <t>Amplatzer</t> Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.
Amplatzer Vascular Plug Ii Avp Ii, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+vascular+plug+ii/pm41709488-27-6-11?v=Abbott+Laboratories
Average 86 stars, based on 1 article reviews
amplatzer vascular plug ii avp ii - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer vascular plugs ii avps
Transesophageal echocardiogram (TEE) with color Doppler showing severe mitral paravalvular leak originating between 2 previously deployed <t>Amplatzer</t> vascular plugs and adjacent to the left atrial appendage . (A) Two-dimensional TEE; (B) three-dimensional TEE.
Amplatzer Vascular Plugs Ii Avps, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc13198090-22-12-17?v=Abbott+Laboratories
Average 86 stars, based on 1 article reviews
amplatzer vascular plugs ii avps - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

86
Abbott Laboratories amplatzer ii vascular plug
Transesophageal echocardiogram (TEE) with color Doppler showing severe mitral paravalvular leak originating between 2 previously deployed <t>Amplatzer</t> vascular plugs and adjacent to the left atrial appendage . (A) Two-dimensional TEE; (B) three-dimensional TEE.
Amplatzer Ii Vascular Plug, supplied by Abbott Laboratories, used in various techniques. Bioz Stars score: 86/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/amplatzer+vascular+plug+ii/pmc12857541-36-2-6?v=Abbott+Laboratories
Average 86 stars, based on 1 article reviews
amplatzer ii vascular plug - by Bioz Stars, 2026-08
86/100 stars
  Buy from Supplier

Image Search Results


(A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm Amplatzer Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.

Journal: Journal of Vascular Surgery Cases, Innovations and Techniques

Article Title: Use of a physician-modified candy plug to rescue gutter leak arising from a collapsed candy plug

doi: 10.1016/j.jvscit.2026.102175

Figure Lengend Snippet: (A) Final deployment of the physician-modified candy plug (CP) ( red arrows indicate the proximal and distal struts of the modified stent graft). An 18-mm Amplatzer Vascular Plug II is positioned within its constrained central lumen ( blue arrows indicate the proximal and distal nitinol mesh lobes). (B) Complete thrombosis of the false lumen (FL) with cessation of retrograde flow above the CP devices. The vascular plug within the physician-modified CP is indicated by the blue arrow . (C) Volume-rendering technique reconstruction demonstrating the thoracic endovascular repair (TEVAR) and CP devices.

Article Snippet: The constrained central lumen of the physician-modified CP was plugged with an 18-mm Amplatzer Vascular Plug II (Abbott Vascular) ( , A ).

Techniques: Modification

Transesophageal echocardiogram (TEE) with color Doppler showing severe mitral paravalvular leak originating between 2 previously deployed Amplatzer vascular plugs and adjacent to the left atrial appendage . (A) Two-dimensional TEE; (B) three-dimensional TEE.

Journal: Journal of the Society for Cardiovascular Angiography & Interventions

Article Title: Secure the Plug: Ultimate Structural and Intervention Complex Paravalvular Leak Closure and Simultaneous Left Atrial Appendage Closure – A Case Report

doi: 10.1016/j.jscai.2026.104274

Figure Lengend Snippet: Transesophageal echocardiogram (TEE) with color Doppler showing severe mitral paravalvular leak originating between 2 previously deployed Amplatzer vascular plugs and adjacent to the left atrial appendage . (A) Two-dimensional TEE; (B) three-dimensional TEE.

Article Snippet: The PVL was previously managed percutaneously with the deployment of two 6-mm Amplatzer vascular plugs II (AVPs) (Abbott) in 2016; a residual leak was noted, but was trivial.

Techniques:

Left ( A) Fluoroscopic view showing the successful deployment of 34-mm Amplatzer Amulet device, demonstrating a complex multilayered plug configuration used to seal the residual mitral paravalvular defect. Right ( B ) Transesophageal echocardiogram (TEE) images postdeployment showing optimal device position and stability with resolution of paravalvular regurgitation and no interference with prosthetic valve function. Bottom ( C ) TEE with color Doppler showing plug in place and resolution of paravalvular leak. ( D ) Three-dimensional (3D) TEE picture of the Amplatzer vascular plug II and the left atrial appendage occlusion.

Journal: Journal of the Society for Cardiovascular Angiography & Interventions

Article Title: Secure the Plug: Ultimate Structural and Intervention Complex Paravalvular Leak Closure and Simultaneous Left Atrial Appendage Closure – A Case Report

doi: 10.1016/j.jscai.2026.104274

Figure Lengend Snippet: Left ( A) Fluoroscopic view showing the successful deployment of 34-mm Amplatzer Amulet device, demonstrating a complex multilayered plug configuration used to seal the residual mitral paravalvular defect. Right ( B ) Transesophageal echocardiogram (TEE) images postdeployment showing optimal device position and stability with resolution of paravalvular regurgitation and no interference with prosthetic valve function. Bottom ( C ) TEE with color Doppler showing plug in place and resolution of paravalvular leak. ( D ) Three-dimensional (3D) TEE picture of the Amplatzer vascular plug II and the left atrial appendage occlusion.

Article Snippet: The PVL was previously managed percutaneously with the deployment of two 6-mm Amplatzer vascular plugs II (AVPs) (Abbott) in 2016; a residual leak was noted, but was trivial.

Techniques: